AT10

Weighing Instrumentation Weight Transmitters

DOWNLOADS

  • DIN rail mounting
  • Terminal 20-pin for the 4 load cells connection
  • Power supply 20 ÷ 28 Vdc
  • Input signal from 3 to 30mV
  • Adjustment Zero and Full Scale by dip-switch and multi-turn trimmer

TECHNICAL SPECIFICATIONS AT10

Power supply:

24 Vdc ± 15%
Cells Power: 10 Vdc (max 4 x 350 ohm cells)
Maximum power: 6 W
Analog outputs: 0 to 5 VDC, 0 to 10 VDC, 0 to 20 mA, 4 ÷ 20 mA
Full scale (FS): 3 ÷ 30 mV / V
Linearity: ± 0.02% FS
Operating temperature: -10 to +50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 to +70 ° C
Thermal stability: 20 ppm / ° C
Temperature drift: 0.005% FS / ° C
Zero Calibration: Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Calibration of full scale (fs): Adjusting through 4 dip-switches precise adjustment through to 20 laps trimmer
Analog filter (for V output only): Adjustable through trimmer monoturn 270 ° C
Mounting: DIN rail
Dimensions: 133 x 92 x 56 mm (L x H x D)
Connections: Screw terminal blocks 5.08 mm pitch
CE conformity: EN50081-1, EN5002-2 EMC, LVD EN61010-1
Options: Power supply 115 or 230 VAC 50/60 Hz (for DIN rail)
 
 

 