DAT 100/RS485

Weighing Instrumentation Weight Transmitters

DOWNLOADS

  • High performance and long-term reliability
  • Mounting "snap-on" DIN rail (EN50022)
  • Configuration and calibration executable from the front panel with the certificates of the transducers, or with known weights
  • RS232 and RS485 outputs, ASCII and Modbus RTU protocols 
  • The width dimensions allow to place a large number of transmitters within the electrical automation panels
  • Interfacing with barriers Intrinsically Safe for use in hazardous areas

TECHNICAL DAT 100 / RS485

transducers Power:

4 V (max 4 x 350 ohm cells)
Measuring range: -4 to +4 mV / V
Input sensitivity: 00:02 V / division
Linearity: <0.01% FS
Thermal drift: <0.001% FS / ° C
Display: 5 digits, red 7-segment LED, height 7 mm
Status LEDs: 2 red
A / D converter: 24-bit
Internal resolution: of 16,000,000 points
Viewable resolution: 60,000 displayable divisions on net weight
Divisions value (selectable): 0001 ÷ 50
Filter: selectable 0.2 to 25 Hz
Keyboard: 3 mechanical buttons (behind the red door)
Power tool: 24 Vdc ± 10% - input power 2 W
Operating temperature: -10 ÷ + 50 ° C (max 85% relative humidity without condensation)
Storage temperature: -20 ÷ + 60 ° C
Logic outputs: 2 optisolate; MAX 24 VDC / 100 mA cad
Logic inputs: 2 optoisolated PNP at 24 VDC (external power supply)
Serial Ports: RS232 half duplex with ASCII protocol or Modbus RTU full duplex RS485 with ASCII protocol or Modbus RTU
Baud rate: 2400 ÷ 115200 Selectable
Transmission distance: 15 m (RS232); 1000 m (RS485)
Regulatory Compliance: EN61000-6-2, EN61000-6-3 EMC; EN61010-1 for Electrical Safety
Electric connections: Screw terminal blocks 5.08 mm pitch
 
 

 