DAT 400 THEORETICAL CALIBRATION

 

DAT 400 CALIBRATION WITH A PROOF WEIGHT

 

DAT 400 PBL

Weighing Instrumentation Weight Transmitters

DOWNLOADS

  • Available with a 220 Vac, high performance and reliability
  • USB, RS232 or RS422 / RS485, MODBUS RTU or ASCII protocols
  • Upload and download function for programming with TESTER 1006
  • Connects directly to the PROFIBUS fieldbus and DEVICENET with optional internal card
  • Up to 32 addressable units, connected to a PC or PLC
  • Linearization on 10 points
  • Executable calibration with transducers Certificates
  • Configuration and calibration from the front panel or from PC via the USB serial port, RS232 / RS485 with the Innovation Program ™ (MS Windows)

TECHNICAL DAT 400 PBL

Encoder supply: 5 V (max 6 350 ohm cells)
Measuring range: ÷ -0.5 +3.5 mV / V (optional ÷ -3.9 +3.9 mV / V)
input sensitivity: 00:02 microV / Division
Linearity: <0.01% of full scale
Temperature drift: <0.001% FS / ° C
Display: 6 digits, red 7-segment LED, height 14 mm
A / D converter: 24-bit
Internal resolution: > 16,000,000 points
viewable resolution: 60,000 displayable divisions on the net weight
settable decimal: 0.0; 0.00; 0,000
Filter: selectable from 0.1 to 25 Hz
Keyboard: 4 keys tactile feedback disabled if
Power tool: 230 Vac 50 Hz - Power consumption 5 W
Operating temperature: -10 To + 50 ° C (max 85% humidity non-condensing)
Storage temperature: -20 To + 70 ° C
logic outputs: 2 opto-isolated; MAX 24 VDC / 100 mA each
Logic inputs: 2 opto-isolated 24V dc PNP (external power supply)
Serial port: USB, RS232C or RS422 / RS485 with Modbus RTU or ASCII protocols
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
fieldbus protocol: PROFIBUS, DEVICENET, ETHERNET, PROFINET (optional)
Communication with other fieldbus: CANopen, Modbus-Plus and others, Precise Gateway 3000 (optional)
Peak Hold function: for dynamic measurements
Baud rate: 2400, 9600, 19200, 38400, 115200 Selectable
Optional analog output: optically isolated 16 Bit Voltage: 0 to 5 / 10V (R min10 K Ohm) Current: 0/4 to 20mA (R max 300 Ohm)
Regulatory Compliance: EN50081-1, EN50082-2 for EMC; EN61010-1 for Electrical Safety
Electric connections: Terminal screw, step 5 mm and 4 PG9
Dimensions and weight: 298x260x140 (WxHxD)
Hole spacing (4): 200x161 (WxH)
 
 

 

Product & Technology News

Correct installation of a weighing system

Product Selector

Pavone

Application Selector

Pavone

Download Catalogue