UWT 600
Weighing Instrumentation Weight Transmitters
|
|
|
-
DIN rail mounting
-
RS232 and RS422 / RS485 output, ASCII protocol or MODBUS RTU
-
High performance and reliability
Options:
-
PROFIBUS, DeviceNet, Ethernet
-
Analog output
-
Ability to configure the instrument with two options simultaneously
|
|
SPECIFICATIONS UWT 600
transducers Power:
|
5 V (max 8 350 Ohm cells) |
Measuring range: |
÷ -1.5 +3.5 mV / V |
Input sensitivity: |
00:02 MicroV / Division |
Linearity: |
± 0.01% SN |
Thermal drift: |
SN ± 0.001% / ° C |
Display: |
LCD, alphanumeric, backlit, 2 rows x 16 characters |
A / D converter: |
24-bit |
Internal resolution: |
> 16,000,000 points |
Viewable resolution: |
600,000 divisions |
Divisions value (selectable): |
x1, x2, x5 |
Set Decimal: |
0.0; 0:00; 0000 |
Filter: |
selectable 0.1 to 25 Hz |
Keyboard: |
4 membrane keys |
Power tool: |
24 Vdc ± 15% - 12 W |
Operating temperature: |
-10 ÷ + 50 ° C (max 85% relative humidity without condensation) |
Storage temperature: |
-20 ÷ + 70 ° C |
Logic outputs: |
2 relays (contacts cleaned NA) - 115 VAC / 30 VDC, 0.5 A |
Logic inputs: |
2 optoisolated 24 VDC PNP |
Serial port: |
COM1: RS232 COM2: RS422 / RS485 |
Transmission distance: |
15m (RS232C), 1000m (RS422 and RS485) |
Fieldbus protocol: |
PROFIBUS, DEVICENET, ETHERNET (optional) |
Serial protocol: |
ASCII, Modbus RTU |
Baud rate: |
1200 ÷ 115200 selectable |
Analogue output (optional): |
optoisolated 16-Bit Voltage: 0 ÷ 5 / 10V (R min10 K Ohm), Current: 0/4 ÷ 20mA (R max 300 Ohm) |
Regulatory Compliance: |
EN61000, EN61000 EMC; EN61010-1 for Electrical Safety |
Electric connections: |
Terminal screw, step 5 mm |
Dimensions: |
100 x 75 x 110 mm (L x H x D) |
|
|
|
|
|
|