E 70/2
Weighing Instrumentation Atex and Stainless Steel
|
|
|
 |
-
Designed for installation in potentially explosive environments
-
Complete digital programming directly from the front of the instrument
-
RS232 or RS422/RS485, MODBUS RTU or ASCII protocols
-
Suitable for satisfying various needs in the field of industrial weighing: management of level limits, weight control and elaborate dosing procedures
-
Calibration run with certificates of transducers
-
Housing in explosion proof case -also intrinsically safe barriers- as an interface with the load cells
-
Degree of protection IP65/IP66
|
 |
TECHNICAL CHARACTERISTICS E 70/2
|
Transducer power supply: |
max 5 V (max 6 cells of 350 Ohms) through intrinsic safety barriers |
|
Measuring range: |
from transducers with sensitivity from -3.9 to +3.9 mV / V |
|
Input sensitivity: |
0.02 micronV/division |
|
Linearity: |
<0.01% of full scale |
|
Thermal drift |
<0.0003% of full scale / ° C |
|
Display: |
7 digit, 7-segment red LED, height 14mm |
|
A/D converter: |
24 bits |
|
Internal resolution: |
> of 16,000,000 points |
|
Viewable resolution: |
60,000 displayable divisions on the net weight |
|
Settable decimals: |
0.0; 0.00; 0.000 |
|
Filter: |
selectable from 0.2 to 50 Hz |
|
Keyboard: |
14 buttons in ATEX execution |
|
Power supply: |
230 Vdc 50/60 Hz (optional 115 Vdc) max absorption 15VA |
|
Temperature range: |
-10 To +50 ° C (max 85% humidity non-condensing) |
|
Storage temperature: |
-20 ÷ +70 °C |
|
Logic outputs: |
6 relays (contact) MAX 115Vac/30 Vdc, 0.5 A each |
|
Logic inputs: |
6 opto-isolated 12 V cc PNP |
|
Serial port: |
RS232C or RS422/RS485 |
|
Transmission distance: |
15m (RS232C), 100m (RS422 and RS485) |
|
Standard protocol: |
ASCII, MODBUS RTU |
|
Baud rate: |
1200, 2400, 4800, 9600, 19200, 38400, 115200 selectable |
|
Regulatory Compliance: |
EN50081-1, EN5002-2 for EMC; |
|
|
EN61010-1 for Electrical Safety |
|
|
94/9/EC for ATEX II 2 GD; EEx d IIB T6÷T4 |
|
 |
|
|
|
|
|
|