LC 300

Accessories Electronic Overload Guard

DOWNLOADS

  • Redundant system with two independent inputs for load cells, according to category 3 standard EN 13849-1:2008, PL d (corresponding to SIL 2 IEC 62061).
  • Load limiter with double security
  • Alarm for loadcell malfunctioning or power failure
  • Supply from 10 to 30 Vdc
  • 4-digit red led service display
  • Mounting on DIN rail
  • Operating temperature from -10° to +50°C
  • Removable screw terminal blocks 5.08

TECHNICAL CHARACTERISTICS LC 300

Power supply: 10÷30 Vdc
Max consumption: 6 W
Insulation: class III
Display: numeric; 4-digit, 7-segment red led (h 7 mm)
Filter: Selectable 0.25 Hz - 3 Hz
Measuring range: from -3.9 to +3.9 mV/V
Input sensitivity: 0,2 microV
Linearity: <0.01% of full scale
Thermal drift: <0.002% of full scale/°C
Internal resolution: 24 bits
Operating temperature: -10 / +50°C (humidity max 85% non-condensing)
Storage temperature: -20/+60 °C
Keyboard: 4 mechanical keys
Calibration of zero and full scale: executable from keyboard
Material: Polyamide 6.6 UL 94V-0 self extinguishing
Connections: removable screw terminal blocks 5.08
Load cells Input: max 4 350 Ohm for both measuring channels
Interruption control load cell cable: indication on the display and via relay
Logic outputs alarm: 4 relay outputs
2 ANALOGUE OUTPUTS: 4÷20 mA (1 per channel)
Resolution: 16 bit
Calibration: digital from the keyboard
Impedance: max 300 Ohms
Linearity: 0.03% of full scale
Thermal drift: 0.002% of full scale/°C
Dim: 136 x 125 x 65 mm (L x H x P); 171 x 125 x 65 mm (L x H x P) Analog
CE Conformity: EN 61000-6-2, EN 61000-6-3 EMC to EN 61010-1 for electrical safety, EN 13849-1 parts of control systems related to safety
ELECTRICAL CONNECTIONS
PIN TERMINAL BOARD 5P (LOAD CELL 1)
1 Shield
2 - Excitation
3 + Signal
4 - Signal
5 + Excitation
PIN TERMINAL BOARD 5P (LOAD CELL 2)
6 Shield
7 - Excitation
8 + Signal
9 - Signal
10 + Excitation
PIN TERMINAL BOARD 14P
1 RP2 Channel 2 Prealarm Relay. COM
2 RP2 Channel 2 Prealarm Relay. NC
3 RP2 Channel 2 Prealarm Relay. NO
4 RP2 Channel 2 Lookout Relay. COM
5 RP2 Channel 2 Lookout Relay. NC
6 RP2 Channel 2 Lookout Relay. NO
7 RP1 Channel 2 Prealarm Relay. COM
8 RP1 Channel 2 Prealarm Relay. NC
9 RP1 Channel 2 Prealarm Relay. NO
10 RP1 Channel 2 Lookout Relay. COM
11 RP1 Channel 2 Lookout Relay. NC
12 RP1 Channel 2 Lookout Relay. NO
13 Power supply -
14 Power supply + (10-30 Vdc)
 
 

 