Power supply: |
230 - Opz. 115 Vac 50/60 Hz - max absorption 15 VA |
Operating temperature: |
+14°F / +104°F (max humidity 85% non-condensing) |
Storage temperature: |
-4°F / +122°F |
Display: |
numerical to 6 digit to high efficiency and wide visual angle |
Reading distance: |
till at 15 mt |
Visualized data: |
acquired weight from load cells or analogic input 0-10V or 4-20mA. Alphanumeric indications and menu of programming |
Functions remote control: |
insertion/cancellation tare, Zero balance, serial transmission running weight, configuration and calibration |
Overall dimensions: |
346 mm x 118 mm x 98 mm (l x h x p) |
Mounting: |
On the wall with 4 holes diam. 6 mm with external lateral distance 335 x 81 mm (width x height) |
Enclosure: |
stainless steel protected against dust |
Connections: |
Circular Connectors ponds, with wiring conductors with screw terminals |
Power load cells: |
5 Vdc/120mA (max 350 Ohms 8 cells in parallel) short circuit protected |
Linearity: |
<0.01% of full scale |
Temperature drift (load cell): |
<0.0003 % of full scale |
Temperature drift (analog input): |
<0.001 % of full scale |
Internal resolution: |
24 bit |
Resolution displayed weight: |
up to 60,000 divisions on the load capacity |
Measuring range (load cell): |
from -1.5 mV/V to +3.5 mV/V |
Acquisition frequency weight: |
6 Hz - 25 Hz |
Digital Filter: |
selectable from 0.2 Hz to 25 Hz |
Number of decimal weight: |
from 0 to 3 decimal places |
Logic output: |
N° 3 relays |
Uart port: |
Rs232c/Rs485 standard; Remote control with 4 key for configuration and operating commands; Extern RF 868 MHZ interface (options); Ethernet protocol (options); Profibus protocol (options) |
Conforms to standards: |
EN61000-6-2, EN61000-6-3, EN61010-1 |