PSVIS HE 100

Weighing Instrumentation Weight Indicators

DOWNLOADS

  • Weight display for load cells
  • Optional with 0-10 V or 4-20 mA
  • Stainless steel housing with waterproof connections
  • IP65
  • Reading distance up to 35 m
  • Alphanumeric 5 characters/digits display, height 100 mm, with automatically adjusted brightness and also suitable for outside installation
  • Configuration and calibration by remote control
  • Transmissions serial RS232, RS485
  • Ethernet or PROFIBUS DP options

TECHNICAL CHARACTERISTICS PSVIS HE 100

Recommended input: 100 ÷ 240 Vca 50/60 Hz - 25 W
Temperature range: -10°C ÷ +40°C
Storage temperature: -20°C ÷ +50°C
Display: 5 alphanumeric digits of 5 x 7 LED red. LED Surface: 460 x 100 mm Available in a kit including 8-digit (LED surface 780 x 100 mm)
Display brightness: Anti-glare filter and automatic brightness depending on ambient light, suitable for installation even in direct sunlight
Visible data: Weight gained by load cells or analog input 0 to 10 V or 4 to 20 mA; alphanumeric indications and programming menu
Radio control functions: Tare, zero balance, serial transmission current weight, configuration and calibration
Dimensions: 500 x 185 x 115 mm ( L x H x D )
Mounting: On wall with 4 side holes outside Ø 6.5 mm with 510 x 155 mm (W x H)
Container: Stainless steel protect against dust
Electrical connection: Sealed circular connectors, with wiring conductors with screw terminals
Trasducer input voltage: 5 V (max 8 load cells 350 Ohms)
Linearity: <0.01% R.O.
Thermic drift (Load cell): <0.0003% R.O./°C
Thermic drift (Input): <0.001% R.O./°C
Internal resolution: 24 bit
Visible resolution: > 60.000 divisions
Measuring range: -1.5 ÷ +3.5 mV/V
Acquisition frequency: 6 ÷ 25 Hz
Filter: 0.2 Hz ÷ 25 Hz adjustable
Set decimal: 0 ÷ 3 decimal figures
Serial door: RS232C / RS422 / RS485
Transmission distance: 15m (RS232) e 1000m (RS422/RS485)
Protocol: ASCII + Programmable custom protocols
Baud rate: 1200 ÷ 115200 adjustable
Options: Ethernet and Profibus DP protocols
Regulatory compliance: EN61000-6-2, EN61000-6-3, EN61010-1
 
 

 