MC 302/ETHERNET

Weighing Instrumentation Weight Indicators

DOWNLOADS

  • Fulfills various needs in the field of weighing, from simple level setpoint to complicated batching procedures
  • Production of special software
  • 24-bit A/D converter 
  • Fiscal memory up to 160.000 weighings -option-
  • Totalisation of dosed weights according to recipe and component
  • RS422/485 serial outputs with Modbus RTU protocol 
  • Ethernet 
  • 50 different recipes can be stored and automatically printed
  • Upload and download function for programming by TESTER 1006

TECHNICAL CHARACTERISTICS MC 302/ETHERNET

Trasducer input voltage: 5 V (max 8 load cells 350 Ohm in parallel)
Measuring range: -3.9 ÷ +3.9 mV/V
Input sensitivity: 0.02 µV/ per count
Linearity: <0.01% of full scale
Gain drift: <0.0003% full scale/ °C
A/D Converter: 24 bit
Internal resolution: > 16.000.000 counts
Visible resolution: 600.000 divisions displayed on net weight
Divisions value (adjustable): x1, x2, x5
Set decimal: 0.0 ; 0.00 ; 0.000; 0.0000
Filter: 0.2 ÷ 50 Hz. 100 Hz during dosage
Tool voltage: 230 Vac ±10% - 50/60 Hz absorbed power 7 VA (115 Vac on demand)
Temperature range: -10 ÷ +50°C
Storage temperature: -20 ÷ +70°C
Logic output: 6 relays (NA) MAX 115 Vac /30 Vdc 0.5 A cad.
Logic input: 8 optoisolated 12 / 24 Vdc PNP
Serial door: COM1: RS232 half duplex COM2: RS422/RS485 half duplex
Transmission distance: 15m (RS232C), 1000m (RS422 and RS485)
Protocol: ASCII, Modbus RTU
Baud rate: 1200 ÷ 115200 adjustable
Regulatory compliance: EN45501 for Metrological Norms EN50081-1 and EN50082-2 EMC EN61010-1 for Electrical Safety
Fiscal optional memory: > 160.000 weighed
Power supply: 12 to 24 VDC -10% to +15%, 15 VA
 
 

 