Optimum Series Absolute Displacement Sensor - Specification
Generic Product Types
LVDT
OP1.5
OP6
OP10
OP12.5
OP25
Digital Output (Orbit®)
DO3
DO12
DO20
DO25
DO50
Measurement
Measurement Range LVDT (mm)
±1.5
±6
±10
±12.5
±25
Measurement Range ORBIT (mm)
3
12
20
25
50
Linearity (% FSO)
<0.25
<0.25
<0.25
<0.25
<0.25
Resolution µm (Note 1)
<0.10
<0.10
<0.10
<0.20
<0.40
Pre-travel ±0.5 mm (Guided Versions only)
1.78
1.53
1.53
2.33
2.10
Post Travel ±0.5 mm (Guided Versions only)
1.20
1.67
1.67
2.47
2.30
Temperature Coefficients (%FSO/°C) LVDT
<0.05
<0.05
<0.05
<0.05
<0.05
Temperature Coefficients (%FSO/°C) DC/4-20mA
<0.07
<0.07
<0.07
<0.07
<0.07
Tip Force ±20% (Horizontal at middle of range) N
0.66
0.94
0.94
0.93
0.50
Mechanical
Nominal Mass (g) LVDT
7
12
12
20
20
Nominal Mass of Core (g)
1.5
2.5
2.0
3.5
4.0
Body diameter (mm)
9.52
Case material
400 Series Stainless Steel
Core material
Nickel Iron
Cable Standard Type/Length (m) (Note 2)
F.E.P. / 3 Style A or B
Electrical Interface (LVDT)
Energising Voltage (Vrms) at 5 kHz
1-5
Energising Current at 5kHz (mA/V)
6.0
4.5
3.2 (3)
7.0
1.25
Sensitivity at 5kHz ±5% mv/V/mm
108
78
85 (3)
67
25
Electrical Interface (Orbit)
Bandwidth
Up to 460 Hz (selectable)
Output
Solartron Orbit
Power (VDC)
5±0.25 @ 0.06A
Sealing
IP43
Environmental
Operating Temperature (°C)
-40 to +150
Storage Temperature (°C)
-40 to +150
Sealing
Splash Proof
Note 1: Resolution specification is only applicable to ORBIT digital transducers. The resolution of LVDT transducers is effectively infinite and is only limited by the conditioning electronics
Note 2: Cable Style A comprises of individual twisted cores , Style B comprises a sheathed and screened cable