Technical specifications    

				

       Expert Key

       Device type

        100

        200

       Analog inputs

        14

        28

       Current source for RTD
        4         8
       Sensor types          mV, mA, thermocouples, RTD, Pt100(0)
       Resolution          18 Bit
       Sampling rate          100 kHz
       Measurement range          ± 100, 200, 500 mV; ± 1, 2, 5, 10 V
       Compensation           yes / 1         yes/ 2
       Galvanic isolation          yes
       Analog outputs          2         2
       Resolution          16 Bit
       Max. output rate          50 Hz
       Output voltage / current          0 ... 10 V / ± 10 V / 0 ... 20 mA / 4 ... 20 mA / ± 20 mA
       Galvanische Trennung          yes
       Digital inputs ...          8 to 12            1
       Input voltage / current          5 V, 12 V, 24 V, 48 V / 2,7 mA
       Logic voltage level          < 2.5 V = low / > 3 V high
       Max. input frequency          1 MHz or 10 kHz
       Galvanic isolation          yes
       ... with counter function          8 to 12 1
       Counter resolution          64 Bit

       Max. input frequency /resolution

         1 MHz / 1 µs or 10 Hz / 100 µs
       Measurement range          0.1 Hz ... 1 MHz or 10 kHz

       Max. input voltage / current

         5 V, 12 V, 24 V, 48 V / 1,5 mA
       Galvanic isolation          yes
       Digital outputs ...          4 to 8 1

       Max. switching voltage / current

         30 V / 1 A or 40 V / 0,75 A or 50 V / 0,6 A
       Max. output rate          10 Hz
       Galvanic isolation          yes
       ... with PWM function          4        1
       Duty cycle           1:100 ... 1:500

       Max. switching voltage / current

          30 V 1 A or 40 V / 0,75 A or 50 V / 0,6 A
       PWM basic frequency           5 Hz bis 10 kHz
       Galvanic isolation           yes
       General technical information
       Sensor connection           via srew terminals with 0.14 ... 2,5 mm² openings
       Power supply           external power supply
       Max. power input           6 Watt
       Power supply           9 ... 24 VDC
       Temperature range           0 ... 50 °C

       Environmentally friendly

          RoHS conform

       Interfaces: USB or Ethernet

          USB 2.0 high speed / LAN 100BaseT

       Expert Key L 100 / 200 dimensions

          50 x 185 x 215 mm

       Expert Key L 100 / 200 weight

          750 g

       Expert Key C 100 / 200 dimensions

          57 x 280 x 208 mm

       Expert Key C 100 / 200 weight

          1.500 g

       Expert Key P 100 / 200 dimensions

          495 x 135 x 305 mm

       Expert Key P100 / 200 weight

          6.500 g

       Expert Key M 100 / 200 dimensions

          470 x 175 x 355 mm

       Expert Key M 100 / 200 weight

          5.100 g
 
 
 

                                                                                                                                                                                      

 Back to the Top

Acquisition and storage


					

					

ProfiSignal Go is the intuitive software for storing measurement data, for displaying trends, and for analysis and export functions.

Current measurement data can be observed online in one trend while users evaluate archived data in another.

Running ProfiSignal Go is extremely simple. It takes just a few mouse clicks to go from sensor connection to trend output. Its simple

operation makes ProfiSignal Go a joy to use. ProfiSignal Go is supplied free of charge with each Expert device.

 

   

                                                                                                                                                                              

Back to the Top

Limitless trends


					

					

There are virtually no limits to the portrayal of online and offline measurement data as trends. Archived and online measurement

data can be evaluated without interrupting the current measurement procedure. This is a unique function and is especially valued by customers.

As well as y(t) and y(x) trends, logic trends are also available. The ProfiSignal Go toolbox contains trend functions such as moveable axes,

zoom functions, cursors and markers, and data exports in CSV or EMF formats. This useful toolbox is simple to use.

Configured trends can be saved and reused later.

Upgrading to ProfiSignal Basic and ProfiSignal Klicks is possible at any time to add functions for visualization and automation.

 

                                                                                                                                                                           

Back to the Top

Alarm functions


					

					

As well as trend functions, ProfiSignal Go also provides alarm management. A global alarm list simply and clearly portrays alarm notifications

in a table. Alarm settings for the monitoring of over-runs, under-runs, process violations, status outcomes etc. are configured using the

DataService / Configurator software. Other actions such as emails, text messaging or triggering a digital output may also be performed.

Upgrading to ProfiSignal Basic and ProfiSignal Klicks is possible at any time to add functions for visualization and automation.

 
 
 

 