RCA15 Rack Mounted Intelligent Strain Gauge Amplifier

RCA15 Rack Mounted Intelligent Strain Gauge Amplifier

Features |  Specification | Dimensions |  Downloads | Suggested Instrumentation | Options  | Applications     

  • Selectable Strain Gauge sensitivity from 0.5 to 200mV/V
  • Simple one pass auto calibration
  • Auto Tare
  • Isolated analogue outputs 4-20mA and 0-10V outputs
  • 10V @ 1.4A excitation for each rack
  • High accuracy/low drift
  • 3U 19" rack frame
  • 10 year data retention
  • Digital programming, calibration & display
  • Optional Communications for each channel include RS485, RS232
  • Optional 2 setpoints/relays for each channel

The intelligent Strain Gauge amplifier offers both 4 to 20mA and 0 to 10 volt  analogue outputs, from any standard Strain Gauge input. Ease of calibration and setting of the analogue output range, make the modules extremely user friendly; being set up by a simple hand held plug in programmer or a built in programmer/display.
Auto Tare and Peak Hold (if set) on the analogue output are operated via volt free contact closures.

Output options include:-

Relay Set Points (Programmed in engineering units; with In Flight compensation and Hysteresis settings available for control or alarm purposes)

Communications:-

To read any value, change set points or any other parameter via:
RS232/RS485 (RC3) - Formats MANTRABUS, ASCII, MODBUS RTU
Printer Activated by a contact closure, displays the current live value, with header message, engineering units, auto incrementing batch number and a real time if required.

  Back to the To

Input Details

The input is suitable for any full wheatstone bridge sensor and transducer excitation voltage 9.6 volts 1.0A (common to all channels).

Compensation

by ± sense wires for cable connection, voltage drops and any variation in the excitation supply.

Load cell sensitivity

is preset via DIL switches to 0.5, 0.8, 1.0 1.25, 1.5, 2.0, 2.5, 3.5, 5,10, 20, 50, 100 or 200mV/V.

Initial offset

≤±0.15mV (15µV/V) which is cancelled during auto calibration.

Speed

10 readings per second with a digital filter to reduce speed.

Accuracy

is 90 days ±0.08% of reading, ±0.05% FSD (typically)

Drift

is ±0.002% per degree C @ 2.5mV/V (typically)

Resolution

15 bit (4.5 digits)

Contact inputs

Available for auto tare, print and peak hold reset and are volt free

Rack Mounted Load Cell Amplifiers

Two versions are available to mount in the standard 19” rack

Version 1 (RL1)

comprises an amplifier which is programmed via a hand held, plug in programmer. This version allows for the fitting of the 12 amplifiers.

Version 2 (RL2)

comprises an amplifier which has a front panel mounted LCD display; program buttons are accessed through 2.2mm apertures in the panel. This version allows for the fitting of 8 amplifiers.

Analogue Outputs

Drive

4-20mA up to 1Kohm and 0-10 volts up to 2mA.

Accuracy

4-20mA ±0.15% of range (typically) 0-10V ±2% before calibration

Resolution

13 bit (Settling time 0.25 secs to 1% of step change)

Isolation

±130V RMS or DC max to analogue input or any other port.

Data Retention/Protection

Retention

10 years for set up values, minimum of 100,000 write cycle

 

Protection of data and function(s) Watchdog timer giving repeat auto resets.

 

Impending power detection and hold off.

 

Keypad security and time out.

Options Available

2 set points

Output through 5A, 230V ac SPCO relays (volt free contacts with latching and inversion options

Communications Port

20mA loop - enabling up to 254 to be multi dropped to 1 x RS232 via IF25 interface

 

RS485 - enabling up to 32 units to be multi dropped (isolated)

 

RS232 - for 1 to 1 connection and standard printer drive (isolated)

 

Baud Rates - 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)

CE & Environmental

Storage temperature

-20 to +70ºC

Operating temperature

-10 to 50°C

Relative humidity

95% maximum non condensing

Safety/Low Voltage Directive

2006/95/EC

EMC Directive

2004/108/EC

 Back to the Top

rca15 drawing

 Back to the Top

Click here to download - RCA15 Datasheet

Click here to download - RCA15 Instruction Manual

 Back to the Top