RCA15 Rack Mounted Intelligent Strain Gauge Amplifier
|
|

Features | Specification | Dimensions | Downloads | Suggested Instrumentation | Options | Applications
-
Selectable Strain Gauge sensitivity from 0.5 to 200mV/V
-
Simple one pass auto calibration
-
Auto Tare
-
Isolated analogue outputs 4-20mA and 0-10V outputs
-
10V @ 1.4A excitation for each rack
-
High accuracy/low drift
-
3U 19" rack frame
-
10 year data retention
-
Digital programming, calibration & display
-
Optional Communications for each channel include RS485, RS232
-
Optional 2 setpoints/relays for each channel
The intelligent Strain Gauge amplifier offers both 4 to 20mA and 0 to 10 volt analogue outputs, from any standard Strain Gauge input. Ease of calibration and setting of the analogue output range, make the modules extremely user friendly; being set up by a simple hand held plug in programmer or a built in programmer/display. Auto Tare and Peak Hold (if set) on the analogue output are operated via volt free contact closures.
Output options include:-
Relay Set Points (Programmed in engineering units; with In Flight compensation and Hysteresis settings available for control or alarm purposes)
Communications:-
To read any value, change set points or any other parameter via: RS232/RS485 (RC3) - Formats MANTRABUS, ASCII, MODBUS RTU Printer Activated by a contact closure, displays the current live value, with header message, engineering units, auto incrementing batch number and a real time if required.
|
Back to the To
|
Input Details
|
The input is suitable for any full wheatstone bridge sensor and transducer excitation voltage 9.6 volts 1.0A (common to all channels).
|
Compensation
|
by ± sense wires for cable connection, voltage drops and any variation in the excitation supply.
|
Load cell sensitivity
|
is preset via DIL switches to 0.5, 0.8, 1.0 1.25, 1.5, 2.0, 2.5, 3.5, 5,10, 20, 50, 100 or 200mV/V.
|
Initial offset
|
≤±0.15mV (15µV/V) which is cancelled during auto calibration.
|
Speed
|
10 readings per second with a digital filter to reduce speed.
|
Accuracy
|
is 90 days ±0.08% of reading, ±0.05% FSD (typically)
|
Drift
|
is ±0.002% per degree C @ 2.5mV/V (typically)
|
Resolution
|
15 bit (4.5 digits)
|
Contact inputs
|
Available for auto tare, print and peak hold reset and are volt free
|
Rack Mounted Load Cell Amplifiers
|
Two versions are available to mount in the standard 19” rack
|
Version 1 (RL1)
|
comprises an amplifier which is programmed via a hand held, plug in programmer. This version allows for the fitting of the 12 amplifiers.
|
Version 2 (RL2)
|
comprises an amplifier which has a front panel mounted LCD display; program buttons are accessed through 2.2mm apertures in the panel. This version allows for the fitting of 8 amplifiers.
|
Analogue Outputs
|
Drive
|
4-20mA up to 1Kohm and 0-10 volts up to 2mA.
|
Accuracy
|
4-20mA ±0.15% of range (typically) 0-10V ±2% before calibration
|
Resolution
|
13 bit (Settling time 0.25 secs to 1% of step change)
|
Isolation
|
±130V RMS or DC max to analogue input or any other port.
|
Data Retention/Protection
|
Retention
|
10 years for set up values, minimum of 100,000 write cycle
|
|
Protection of data and function(s) Watchdog timer giving repeat auto resets.
|
|
Impending power detection and hold off.
|
|
Keypad security and time out.
|
Options Available
|
2 set points
|
Output through 5A, 230V ac SPCO relays (volt free contacts with latching and inversion options
|
Communications Port
|
20mA loop - enabling up to 254 to be multi dropped to 1 x RS232 via IF25 interface
|
|
RS485 - enabling up to 32 units to be multi dropped (isolated)
|
|
RS232 - for 1 to 1 connection and standard printer drive (isolated)
|
|
Baud Rates - 300, 600, 1200, 2400, 4800, 9600 (19200 MANTRABUS only)
|
CE & Environmental
|
Storage temperature
|
-20 to +70ºC
|
Operating temperature
|
-10 to 50°C
|
Relative humidity
|
95% maximum non condensing
|
Safety/Low Voltage Directive
|
2006/95/EC
|
EMC Directive
|
2004/108/EC
|
|