PFXSP5500WAD

 

Standard product information
Family 
HMI
Series 
SP5000 Series
Size 
10" Wide
Model 
PFXSP5500WAD
Global Code 
PFXSP5500WAD
Product Features 
10" Wide DC (Advanced Display)
Repair Status 
✔ (Maintenance service is available, able to be maintained.)
 
Display specifications
Display type 
TFT Color LCD
Display size 
10.1"
Resolution 
1,280 x 800 pixels (WXGA)
Auto scaling 
Not equipped
Effective display area 
W216.96 x H135.6 mm [W8.54 x H5.34 in.]
Display colors 
262,144 colors
Backlight 
White LED (Not user replaceable. When replacement is required, contact your local distributor.)
Backlight service life 
50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%)
Brightness control 
0 to 100 (Adjusted with touch panel or software)
Brightness sensor 
Not equipped
Touch panel type 
Resistive Film (analog)
Touch panel resolution 
1,024 x 1,024
Touch panel lifetime 
1,000,000 times or more
 
Electrical specifications
Rated input voltage 
12 to 24 Vdc
Input voltage limits 
10.8 to 28.8 Vdc
Allowable voltage drop 
12 Vdc: 1.25 ms or less
24 Vdc: 5 ms or less
Power consumption 
Max. 8.5 W
Backlight adjusted (20%): 5 W or less
Backlight OFF (Stand-by mode): 2.5 W or less*1
In-rush current 
30 A or less
Noise immunity 
Noise Voltage : 1,000 Vp-p
Pulse Duration : 1 µs
Rise Time : 1 ns
(via noise simulator)
Voltage endurance 
1,000 Vac, 20 mA for 1 minute (between power terminal and FG terminals)
Insulation resistance 
500 Vdc, 10 MΩ or more (between power terminal and FG terminals)

*1Power consumption for Display Module only

Environmental specifications
International safety standards 
abs.gifbv.gifccs.gifce.gifclassnk.gifctick.gifeac.gifex.gifkc.gifkcs.giflr.gifnepsi.gifrina.giful508.giful508ansi.gifdnv_gl.gif
Surrounding air temperature 
0 to 60 °C [32 to 140 °F]
Storage temperature 
-20 to +60 °C [-4 to 140 °F]
Ambient humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Storage humidity 
10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
Dust 
0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
Pollution degree 
For use in Pollution Degree 2 environment
Corrosive gases 
Free of corrosive gases
Air pressure (altitude range) 
800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
Vibration resistance 
IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.]
9 to 150 Hz fixed acceleration: 9.8 m/s2
X, Y, Z directions for 10 cycles (approx. 100 min.)
Concussion resistance 
IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
Electrostatic discharge immunity 
Contact Discharge Method: 6 kV
Air Discharge Method: 8 kV
(IEC/EN61000-4-2 Level 3)
 
Structural specifications
Grounding 
Functional grounding: Grounding resistance of 100 Ω, 2 mm2 (AWG 14) or thicker wire, or your country’s applicable standard (same for FG and SG terminals).
Cooling method 
Natural air circulation
Structure 
IP66F, IP67F, Type 4X (indoor use only)/13*2
External dimensions 
W268.5 x H198.5 x D67 mm [W10.57 x H7.82 x D2.64 in.]
Panel cut-out dimensions 
W255 x H185 mm [W10.03 x H7.28 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]*3
Weight 
2.5 kg [5.5 lb] or less*4

*2The front face of the unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the unit's level of resistance is equivalent to these standards, oils that should have no effect on the unit can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the unit's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the unit and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the unit, be sure to confirm the type of conditions that will be present in the unit's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

*3For dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.

*4Display module only.

Dimensions
External dimensions 

Display module and box module combination

 

sp5500wa_with_box_module_dimensions_e.gif

 

Panel cut-out dimensions 
A B C
255 (+1/-0) mm
[10.04 (+0.04/-0) in.]
185 (+1/-0) mm
[7.28 (+0.04/-0) in.]
1.6 to 5 mm
[0.06 to 0.2 in.]
External dimensions with cable 

 

sp5500wa_with_box_module_cable_dimensions_e.gif

 

(Image of Open Box)

*1Rotation area of the fastener

*2Pitch of center of installation fastener screws

 
 

 

Product and Technology News

PS6000 makes the next stage of your digital transformation

Product Selector

Proface

Application Selector

Proface

Download Catalogue