ATM/GR
 

DOWNLOADS

 

OVERVIEW

 

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Two potential free switches (48 V, 2 A, 60W)
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Materials: Stainless steel, Titanium
  • Output signal 0 … 20 mA / 4 … 20 mA
  •  

Customer benefits

  • Pressure measuring range: 100 mbar … 1000 bar
  • Two potential free switches (48 V, 2 A, 60W)
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Materials: Stainless steel, Titanium
  • Output signal 0 … 20 mA / 4 … 20 mA
Back to Top

SPECIFICATIONS

Pressure measuring range (bar)

  0.1 ... 0.5, (1) > 0.5 ... 2 > 2 ... 25
Overpressure 3 bar 3 x FS (≥ 3 bar) 3 x FS
Burst pressure, (5) > 200 bar > 200 bar > 200 bar
Accuracy, (6) (± % FS) ≤ 0.5 / ≤ 0.25 ≤ 0.5 / ≤ 0.25 / ≤ 0.1 ≤ 0.5 / ≤ 0.25 / ≤ 0.1
Thermal shift, (± % FS/°C)      
Zero point 0 ... 70°C ≤ 0.06 ≤ 0.03 ≤ 0.015
Zero point -25 ... 85°C ≤ 0.08 ≤ 0.04 ≤ 0.02
Span 0 ... 70°C ≤ 0.015 ≤ 0.015 ≤ 0.015
Span -25 ... 85°C ≤ 0.02 ≤ 0.02 ≤ 0.02
Long term stability, (7) < 0.5% FS / < 4 mbar < 0.2% FS / < 4 mbar < 0.1% FS / < 0.2% FS
  > 25 ... 600, (2), (3), (4) > 600 ... 1000, (2)
Overpressure 3 x FS (≤ 850 / ≤ 1500 bar) 1500 bar
Burst pressure, (5) > 850 / ≤ 1500 bar > 1500 bar
Accuracy, (6) (± % FS) ≤ 0.5 / ≤ 0.25 / ≤ 0.1 ≤ 1 / ≤ 0.5 / ≤ 0.25
Thermal shift, (± % FS/°C)    
Zero point 0 ... 70°C ≤ 0.015 ≤ 0.015
Zero point -25 ... 85°C ≤ 0.02 ≤ 0.02
Span 0 ... 70°C ≤ 0.015 ≤ 0.015
Span -25 ... 85°C ≤ 0.02 ≤ 0.02
Long term stability, (7) < 0.1% FS / < 0.2% FS < 0.1% FS / < 0.2% FS

Temperature range

   
Operating temperature -25 ... 85 °C
Process temperatur -40 ... 150°C
Storage temperatur -25 ... 85°C

Electrical specifications

  [SpalteLeer]
Analog output 0 ... 20 mA / 4 ... 20 mA
Power supply 10 ... 33 VDC
Current consumption, (1)
Circuit diagram
Load resistance
Switches  
Switching power, (max.) 60 W
Setting range 0 ... 100% FS
Type SPDT (Relais)
Number of switches 2 (independent)
Switching current, (max.) 2 A
Adjustment Potentiometer
Switching voltage, (max.) 48 VDC
Switching functions
Description Pressure is below both set points: both relais are selected.

Physical specifications

Back to Top

CERTIFICATES

 

 CE Declaration of Cinfirmity 2016-04-13

 RoHS

 
 

 

Product and Technology News

Conductivity, Temperature, Depth

Product Selector

STS

Application Selector

STS

Download Catalogue