MCT S 1302

Weighing Instrumentation Atex and Stainless Steel

DOWNLOADS

  • Touch screen weight indicator perfect for any type of weighing. For desk, wall and panel mounting
  • Practical, easy to install and use
  • Perfect for static weighing and loading-unloading and multicomponent dosage
  • Customizable according to necessity & multilingual menu
  • Available in Profinet, Ethernet IP, Ethernet, EtherCAT
  • 6 inputs and 6 outputs (optoisolated 24 Vdc)
  • Internal data memory 64 Kbytes expandable up to 1024 Kbytes
  • Fieldbus + analog output on board at the same time
  • Option: II3(3)G Ex nR(ic IIC Gc) IIC T6 Gc  II3(3)D Ex tc (ic IIIC Dc) IIIC T85°C DcX -10°C<Tamb<+40°C

TECHNICAL CHARACTERISTICS MCT S 1302

Power supply: 5 Vdc (max 8 -350 Ohm- load cells)
Measuring range: -3.9 ÷ +3.9 mV/V
Input sensitivity: 0.02 microV min
Linearity: < 0.01% FS
Temperature drift: < 0.001% FS/ °C
Display: graphic LCD (240x128 pixel)
A/D converter: 24 bit; internal resolution up to 16.000.000
Frequency signal acquisition: 12 ÷ 1000 Hz
Displayable resolution: 999.999 divisions on net weight
Division value (selectable): x1, x2, x5, x10, x20, x50; 4 decimal points
Filter: selectable 0.1÷250 Hz
Power supply: 10-30 Vdc - Power consumption 5 W
Operating temperature: -10/+ 50°C (humidity max 85% no condensation)
Storage temperature: -20 ±+70°C
Logic outputs: 6 opto-isolated; max 24 Vdc/100mA each
Logic inputs: 6 optically isolated 24 Vdc PNP (external power supply)
Additional I/O: up to 4 external modules with 4 in/8-out each (16 in/32 out, total) by independent RS485
Serial ports: 1 USB device + 1 RS232C + 1 RS485/Fieldbus
Optional analogue output: optoisolated 16-Bit Voltage: 0 to 5/10 V (R min10 K Ohm), Current: 0/4 to 20 mA (R max 300 Ohm)
Analog output linearity: < 0,02% FS
Temperature drift analog output: 0,001% FS/°C
Microcontroller: ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB
Data storage: 64 Kbytes expandable up to 1024 Kbytes
Regulatory Compliance: EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety, EN45501 for metrology
Communication protocols: ETHERNET 10/100 with protocols TCP, MODUBUS/TCP, UDP, IP, ICMP, ARP; PROFINET; ETHERNET/IP; ETHERCAT
 
 

 

Product and Technology News

Correct installation of a weighing system

Product Selector

Pavone

Application Selector

Pavone