Power supply: |
5 Vdc (max 8 -350 Ohm- load cells) |
|
Measuring range: |
-3.9 ÷ +3.9 mV/V |
|
Input sensitivity: |
0.02 microV min |
|
Linearity: |
< 0.01% FS |
|
Temperature drift: |
< 0.001% FS/ °C |
|
Display: |
graphic LCD (240x128 pixel) |
|
A/D converter: |
24 bit; internal resolution up to 16.000.000 |
|
Frequency signal acquisition: |
12 ÷ 1000 Hz |
|
Displayable resolution: |
999.999 displayable divisions on net weight |
|
Value divisions (selectable): |
x1, x2, x5, x10, x20, x50; 4 decimal point |
|
Filter: |
selectable 0.1÷250 Hz |
|
Keyboard: |
4 wires resistive touch screen |
|
Power supply: |
10-30 Vdc - Power consumption 5 W |
|
Operating temperature: |
-10/+ 50°C (humidity max 85% no condensation) |
|
Storage temperature: |
-20 ±+70°C |
|
Logic outputs: |
6 opto-isolated; max 24 Vdc/100mA each |
|
Logic inputs: |
6 optically isolated 24 Vdc PNP (external power supply) |
|
Additional I/O: |
up to 4 external modules with 4 in/8-out each (16 in/32 out, total) by independent RS485 |
|
Serial ports: |
1 USB device + 1 RS232C + 1 RS485/Fieldbus |
|
Optional analogue output: |
optoisolated 16-Bit Voltage: 0 to 5/10 V (R min10 K Ohm), Current: 0/4 to 20 mA (R max 300 Ohm) |
|
Analog output calibration: |
keyboard (touch screen) |
|
Analog output linearity: |
< 0,02% FS |
|
Temperature drift analog output: |
0,001% FS/°C |
|
Microcontroller: |
ARM Cortex M0 + 32 bit 256KB Flash reprogrammable onboard from USB |
|
Data storage: |
64 Kbytes expandable up to 1024 Kbytes |
|
Regulatory Compliance: |
EN61000-6-2, EN61000-6-3 for EMC; EN61010-1 for Electrical Safety, EN45501 for metrology |
|
Electrical connections: |
removable screw terminal blocks (3.81mm pitch) |
|
Dimensions: |
150x95x26mm (LxWxH) including terminal blocks; 150x95x56mm (WxHxD) with fieldbus options; drilling template: 138x82mm |
|
Mounting type: |
panel mount |
|
Communication protocols: |
ETHERNET 10/100 con protocolli TCP, MODUBUS/TCP, UDP, IP, ICMP, ARP; PROFINET; ETHERNET/IP; ETHERCAT |