Power Requirements
AC Input Voltage: 3Ø, 187 to 528 VAC, 47 - 63 Hz
(460 VAC for rated performance)
AC Input Current
MP-1250: 17 Arms (15A @ 100 ms soft start)
MP-2500: 35 Arms (15A @ 100 ms soft start)
MP-5000: 70 Arms (15A @ 100 ms soft start)
Output Continuous Current
MD-404: 4 Arms/2.8 Arms (5 kHz/10 kHz)
MD-407: 7 Arms/5 Arms
MD-410: 10 Arms/6.5 Arms
MD-420: 20 Arms/14 Arms
MD-434: 34 Arms/22 Arms
(Current ratings the same for 460V or 230V
operation)
Output Peak Current
MD-404: 8A/5.6A (5 kHz/10 kHz)
MD-407: 14A/10A
MD-410: 20A/13A
MD-420: 40A/28A
MD-434: 68A/44A
(Current ratings the same for 460V or 230V
operation)
Continuous Output Power
(Ratings based on 5 kHz, 460V/230V operation)
MP-1250: 12.5 kW/6.25 kW
MP-2500: 25 kW/12.5 kW
MP-5000: 50 kW/25.0 kW
MD-404: 3.3 kW/1.7 kW
MD-407: 5.8 kW/2.9 kW
MD-410: 8.3 kW/4.2 kW
MD-420: 16.7 kW/8.4 kW
MD-434: 28.3 kW/14.2 kW
Switching Frequency: 5 or 10 kHz
Logic Supply: +21.6 to 26.4 VDC, (Required Accessory)
Encoder Supply Output: +5 VDC, 250 mA
System Efficiency: 90%
Regeneration
Internal Energy Absorption—System Bus Capacitance
Power Modules (460V/230V):
MP-1250: 110 Joules / 236 Joules
MP-2500: 183 Joules / 393 Joules
MP-5000: 293 Joules / 629 Joules
Drive Modules (460V/230V):
MD-404: 8 Joules / 17 Joules
MD-407: 17 Joules / 37 Joules
MD-410: 26 Joules / 55 Joules
MD-420: 37 Joules / 79 Joules
MD-434: 37 Joules / 79 Joules
Integral Transistor connected to an external resistor:
MP-1250: 30 Ohm minimum, 6 kW max
MP-2500: 30 Ohm minimum, 6 kW max
MP-5000: 9 Ohm minimum, 12 kW max
I/O Supply: +10 to 30 VDC
Power Module Control Inputs
Digital:(2) +10 to 30 VDC, 2.8 kOhm, Sourcing, Optically Isolated
Power Module Control Outputs
Digital:(6) Digital: +10 to 30 VDC, 150 mA, Sourcing, Optically isolated
Relay Contact:(1) AC Interlock, 24 VDC, 5A
Drive Module Control Inputs
Analog: (1) Analog: +/- 10 VDC 14 bit, 100 kOhm, Differential
Analog Max Input Rating: +/- 14 VDC, Differential or Each Input with Reference to Analog Ground
Digital: (5) +10 to 30 VDC, 2.8 kOHm, Sourcing, Optically isolated
Pulse: (1) Pulse, Differential: RS422, 2 MHz/Channel, 50 % Duty Cycle (1) Pulse, Single
Ended: TTL Schmitt
Trigger
Drive Module Control Outputs
Analog: (2) +/- 10 VDC 10-bit, single ended, 20 mA
Digital: (3) +10 to 30 VDC, 150 mA, Sourcing, Optically isolated
Motor OverTemperature: (1) 0 to +5 VDC, single ended
Pulse: Differential: RS422 and TTL compatible, 20 mA/Channel, Sink or Source
Cooling Method
MP-1250: Convection
MP-2500: Integral Fan
MP-5000: Integral Fan
MD-404: Convection
MD-407: Integral Fan
MD-410: Integral Fan
MD-420: Integral Fan
MD-434: Integral Fan
Environmental
Rated Ambient Temperature: 32° to 104°F (0° to 40°C)
Maximum Ambient Temperature: 32° to 122°F (0° to 50°C) with power derating of 3.5% / 1.8°F (1°C) above 104°F (40°C)
Rated Altitude: 3280’ (1000 m)
Maximum Altitude: For altitudes >3280’ (1000 m) derate output by 1%/328’ (100 m)
Vibration: 10 to 2000 Hz @ 2g
Humidity: 10 to 95% non-condensing
Storage Temperature: -13° to 167° (-25° to 75°C)
Ingress Protection: IP-20
Serial Interface
RS232/RS485 Modbus RTU - 9600 to 19.2 kBaud
Internal RS232 to RS485 Converter
Power Module Weight
MP-1250: 8.35 lb (3.78 kg)
MP-2500: 8.35 lb (3.78 kg)
MP-5000: 10.25 lb (4.65 kg)
Drive Module Weight
MD-404: 8.35 lb (3.78 kg)
MD-407: 8.35 lb (3.78 kg)
MD-410: 8.35 lb (3.78 kg)
MD-420: 10.25 lb (4.65 kg)
MD-434: 12.0 lb (5.44 kg)