The FM-3E Ethernet Programming Module transforms EN and MDS drives into fully programmable, single-axis motion controllers and adds 8 digital inputs and 4 digital outputs. Profibus (FM-3PB) and DeviceNet (FM-3DN) options are also available.

For information on FM-3DN (DeviceNet) and FM-3PB (Profibus), see the Options tab on this page.

The FM-3E Ethernet Programming Module allows the user to create programs to sequence motion, I/O control and other machine operations in one environment. Used in conjunction with the Assignments or “virtual wiring” feature, these programs provide the user with a powerful and easy-to-use programming environment.

 
 
  • DeviceNet/FM-3DN (Optional)

    •  Power Consumption: 25 mA
    •  Baud Rates: 125, 250 and 500 kbps
    •  Node Addresses: 00-63
    •  Messaging: Explicit, Polled I/O, Change of State, Strobed and Cyclic
    •  Connection: 5-wire terminal block

    Profibus/FM-3PB (Optional)

    •  Baud Rates: Up to 12 Mbps
    •  Node Addresses: 1-127
    •  Messaging: Cyclic
    •  Connector: DB9

    Ethernet (Optional)

    •  Data Rate: 10/100 base T
    •  Messaging: Modbus TCP/IP, EtherNet/IP, SMTP, and HTTP