Advanced motor control
Digistart IS provides industry leading motor control, featuring constant current, current ramp and adaptive control start methods. Adaptive control is an innovative control method that not only controls motor current but also acceleration. It allows the user to select between early, constant or late acceleration/deceleration depending upon the application requirements. Adaptive control then monitors motor performance by analyzing each start and adjusting accordingly to maintain optimum control.
Adaptive control can benefit many applications. A principle example is pumping where it can be used to eliminate water hammer by allowing the engineer to select the most appropriate deceleration profile for the system.

Compact and flexible installation
The compact Digistart IS features an internal by-pass (on models up to 220 A), reducing space and costs through eliminating the need for external components. In addition, higher power units from 360 A allow the power connections to be configured on the top or bottom of the unit for both input and output, simplifying the cabling. Units can be mounted side-by-side to further reduce cabinet space.
Easy configuration and monitoring
The Digistart IS keypad has
a multi-language graphical display, allowing you to easily set-up and monitor your soft starter. Start-up wizards guide the user through common application configurations and reduce commissioning time. The customizable display also provides real-time performance monitoring and time stamped event logs that can be used for maintenance and diagnostics, helping to improve plant availability.
Fire mode
Digistart IS has an in-built fire mode. This is used in HVAC applications to help protect building occupants in the case of fire by pressurizing escape routes to maintain a smoke free environment. Activation of this feature disables the soft starter protection ensuring it continues to run for as long as possible.
Powerthrough operation
Digistart IS’s powerthrough operation ensures the soft starter will continue to operate using 2 phases if one of the power devices is damaged. This allows you to keep your plant running whilst a long term fix is found.
Increased output
The Digistart IS allows the motor to be connected either in-line (three wire) or using an inside delta configuration (six wire). Inside delta configuration increases the power of the soft starter, meaning a smaller unit can be used. This is a compact, cost efficient solution when replacing wye/delta starters where existing wiring can be used.