3.8-inch Controller
Input Specifications
Rated Voltage |
DC24V |
Maximum Allowable Voltage |
DC28.8V |
Input Method |
Sink/ Source Input |
Rated Current |
6.5mA (DC24V) (IN0, IN2, IN4, IN6)
5mA (DC24V) (Other inputs) |
Input Resistance |
Approx. 3.7kΩ (IN0, IN2, IN4, IN6)
Approx. 4.7kΩ (Other inputs) |
Input Points *1 |
12 |
Common Lines |
1 |
Common Design |
16points / 1 common line |
Operation Range |
ON Voltage |
DC19V or more |
OFF Voltage |
DC5V or less |
Input Delay Time |
OFF→ON |
0.5 to 20ms *2 |
ON→OFF |
0.5 to 20ms *2 |
Input Signal Display |
No LED indicators |
Insulation Method |
Photocoupler isolation |
External Connection |
38-pin connector (used with Output section) |
External Power Supply |
For signal: DC24V |
Output Specifications
|
OUT0 to OUT3 |
OUT4 to OUT15 |
Rated Voltage |
DC24V |
Allowable Voltage Range |
DC20.4V to DC28.8V |
Output Method |
Sink Output |
LT3201-A1-D24-K |
Source Output |
LT3201-A1-D24-C |
Maximum Load Voltage |
200mA/1 point, 1.2A/1 common line |
Minimum Load Current |
1mA |
1mA
(Pulse/ PWM Output Unavailable) |
Output Voltage Drop |
DC0.5V or less |
Output Delay Time |
OFF→ON |
5µs or less
(with output DC24V, 200mA) |
0.5ms or less
(with output DC24V, 200mA) |
ON→OFF |
5µs or less
(with output DC24V, 200mA) |
0.5ms or les
(with output DC24V, 200mA) |
Voltage Leakage (When OFF) |
0.1mA or less |
Clamp Voltage |
39V ±1V |
Type of Output |
Transistor Output |
Common Lines |
1 |
Common Design |
6 points/ 1 common line |
External Connection |
22-pin connector (also used for input) |
Output Protection Type |
Output is unprotected |
Internal Fuse |
2.5A, 125V Chip fuse × 2 (not replaceable) |
Surge Control Circuit |
Zener diode |
Output Points *1 |
6 |
Output Signal Display |
No LED indicators |
Isolation Method |
Photocoupler isolation |
External Power Supply |
For Signal: DC24V |
High-speed Counter/ Pulse Catch Input Specifications
|
High-speed Counter |
Pulse catch Input |
Input *1 |
DC24V Open collector |
DC24V
Open collector |
Single phase
(4 points) |
Douple phase
(1 point or 2 points) |
Input points |
CT0(IN0),
CT1(IN2),
CT2(IN4),
CT3(IN6)
According to user setting |
Use CT0(IN0) and CT1(IN2) in pairs
CT0: Phase A, CT1: Phase B
Use CT2(IN4) and CT3(IN6) in pairs
CT3: Phase A, CT3: Phase B
According to user setting |
IN0, IN2, IN4, IN6
According to user setting |
Minimum Pulse With
(Pulse Input) |
|
|
Count Speed
(Rise, Fall Time) |
|
- |
Phase |
1 phase |
90 degree phase differentional 2-phase signal/ 1-phase + directional signal |
- |
High Speed Count Frequency |
100Kpps |
50Kpps |
- |
Count Edge Designation |
Available |
Not available |
- |
Count Register |
32-bit UP/ DOWN counter |
- |
Counter Mode Charge |
Set through software |
- |
Upper/ Lower Limit Settings |
Not available |
- |
Preload/ Prestrobe |
Available |
- |
Maker Input
(Clear Counter Value) |
-
|
IN3,IN7 |
- |
Pulse/ PWM Output Specifications
|
Pulse output |
PWM output |
Output Points *1 |
4 points |
Output Method |
PLS0 to PLS3
(OUT0 to OUT3)
defined by user |
PWM0 to PWM3
(OUT0 to OUT3)
defined by user |
Load Voltage |
DC24V |
Minimum Load Current |
1mA |
Maximum Output Frequency |
Up to 65kHz possible per point (set through software)
Varies depending on the number of CH of High-speed counter, pulse output. |
Pulse Acceleration |
Available |
Not available |
ON Duty |
50% ±10% (at 65kHz)*3 |
19 to 81% (at 65kHz)*4 |
-
*1 Input / output No. is different by a combination for exclusive specifications.
-
*2 Digital filter can be set intervals of 0.5ms.
-
*3 The ON Duty error (10%) will be reduced if the Output frequency is low.
-
*4 ON duty (effective range) increases as the output frequency setting is lower.
|
|
|
|
|