Specification of PS3710A-T42

PS-3710A 
Model: PS3710A-T42

Thumbnail
  • SSD
  • Expansion Slots x1
  • Ethernet
  • USB
  • CF Card
  • PCMCIA x1
  • DVD-ROM
XGA /   DDR2 256MB-2GB

Pentium(R) M 1.6GHz

Functional Specification

Display Type TFT Color LCD
Display Size 15"
Resolution 1,024 x 768 pixels (XGA)
Dot pitch W0.297 x H0.297 mm [W0.01 x H0.01 in.]
Effective Display Area W304.1 x H228.1 mm [W11.97 x H8.98 in.]
Display Colors 262,144 Colors
Backlight When PS-A Revision 5 and later:
LED (When replacement is required,contact your local GP distributor)
When PS-A Revision 5 and earlier:
CCFL (Replaceable)
Brightness Control 4 Levels (Adjusted with the software)
Contrast Control Not applicable
Backlight Service Life 50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50% or backlight starts to blink)
Supported OS Windows® 2000/Windows® XP/Windows® XP Embedded
CPU IntelR PentiumR M 1.6 GHz
L2 Cache Memory 1 MB (Built in the CPU)
Main Memory DDR SDRAM (PC2700), 256 MB/512 MB/1 GB/2 GB (SO-DIMM socket x 2 slots)
Chipset IntelR 855GME + ICH4
Graphics Accelerator Built in Intel® 855GME
Video Memory 64 MB or less (When using Windows®) UMA Type
Graphics XGA (1,024 x 768 pixels)
BIOS Phoenix® First BIOS Embedded Pro
Clock Accuracy ±180 sec. /month (deviation at room temperature and power is OFF)*1
Touch Panel Type Resistive Film (analog)
Touch Panel Resolution 1,024 X 1,024
Touch Panel Service Life 1,000,000 times or more, Sweeping 100,000 times or more
Touch Panel Interface Internal Serial or Internal USB
Interface IDE 2.5" HDD or SSD x 1 (Primary Master), CF Card Slot (Type II) x 1 (Primary Slave), DVD-ROM Drive (Secondary Master)*2
Serial (COM1) RS-232C (RI/+5 V switch possible), Connector: D-Sub9 (plug)
Serial (COM2) RS-232C (RI/+5 V switch possible), Connector: D-Sub9 (plug)
Serial (COM3) RS-232C (RS-232C/422/485 switch possible), Connector: D-Sub9 (plug)
Serial (COM4) RS-232C (Cannot use with touch panel), Connector: D-Sub9 (plug)
Ethernet (LAN1) IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
Ethernet (LAN2) IEEE802.3i/IEEE802.3u/IEEE802.3ab, 10BASE-T/100BASE-TX/1000BASE-T, Connector: Modular jack (RJ-45) x 1*3
USB (TYPE-A) Conforms to USB2.0 (TYPE-A) x 5, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
Keyboard PS/2 Connector: mini DIN 6 pin
RAS Input: 4 points, Output: 4 points , Rated voltage: DC 24 V , Maximum rated current: 100 mA , External reset input: 1 point, Input voltage: DC 12 to 24 V, Connector: D-Sub25 (plug) x 1
Sound Speaker output, line input, and mic input, Connector: mini-pin jack x 3
PCMCIA PC Card Slot, Card Bus supported connector (*except for Zoomed Video, Sound features): Type II X 1, Type III X 2
Floppy Disk 2-mode 3.5" floppy disk drive x 1
CD/DVD-ROM Drive DVD-ROM Drive (option)
  1. *1     Depending on the operating temperature and age of unit, the clock can deviate ±300 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
  2. *2     Can be switched between Primary Master and Slave via the settings.
  3. *3     Wake On LAN supported.

General Specification

International Safety Standards
  • EU RoHS Directives
  •  
  • UL,cUL(508) Listed
  •  
  • ANSI/CSA(UL508+1604) Listed
  •  
  • CE
  •  
  • KC
     
  •  
  • Gost-R
     
Rated Input Voltage AC 100 to 240 V
Input Voltage Limits AC 85 to 264 V
Rated frequency 50/60 Hz
Allowable Voltage Drop 1 cycle or less(Voltage drop interval must be 1 second or more.)
Power Consumption 150 VA or less
Voltage Endurance AC 1,500 V 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature 5 to 50 ℃: with HDD, 0 to 50 ℃: without HDD
Storage Temperature -20 to +60 ℃
Ambient Humidity 10 to 90% RH (Wet bulb temperature: 29℃ max. - no condensation.)
Storage Humidity 10 to 90% RH (Wet bulb temperature: 29℃ max. - no condensation.)
Dust 0.1 mg/m3 or less (non-conductive levels)
Pollution Degree For use in Pollution Degree 2 environment
Atmosphere Free of corrosive gases
Air Pressure (altitude range) 800 to 1,114 hPa (2,000 m above sea level or less)
Vibration Resistance With HDD: 10 to 25 Hz 4.9 m/s², X,Y,Z directions (30 min), Without HDD: IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)
Noise Immunity Noise Voltage: 1,500 Vp-p, Pulse Duration: 50 ns, 500 ns, 1 μs, Rise Time: 1 ns, (via noise simulator)
Noise Immunity (Fast Transient Burst Noise) Power Line: 2 kV (IEC/EN61000-4-4), COM Port: 1 kV (IEC/EN61000-4-4)
Electrostatic Discharge Immunity Contact Discarge Method: 6kV (IEC/EN61000-4-2 Level 3)
Grounding Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure Equivalent to IP65f NEMA #250 TYPE 4X/12 (When embedding the panel and not using the front panel USB port.)*4
Installation Configuration Embedded panel, VESA Arm
Cooling Method Forced air cooling by the CPU fan
Weight Approx. 8.0kg [17.6lb] max. (unit only)
External Dimensions W395 X H294 X D100mm, [W15.55 X H11.57 X D3.94in.]
Panel Cut Dimensions W383.5 x H282.5 mm [W15.1 x H11.12 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*5
  1. *4     The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
  2. *5     Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].