GP3000 Series panel cutout dimensions/external dimensions difference. No compatibility of control part on the project file. After project conversion, it's necessary to re-allocate I/O and change ladder setting. Display colors is changed from blue mode to Monochrome 16 levels
[ Migration ] Replacing LT Type B/B+/C with GP-3300T/L
Specification Comparison
LT Type B/B+/C
GP-3300T/L
Panel cut-out size difference.
Attachment (CA4-ATM5-01) available
Model No.
Type B+(Color) : GLC150-SC41-XY32KF-24V
Type B(Monochrome) : GLC150-BG41-FLEX-24V
Type B+(Monochrome) : GLC150-BG41-XY32KF-24V
Type C(Monochrome) : GLC150-BG41-RSFL-24V
Color : AGP3300-T1-D24-FN1M
Monochrome : AGP3300-L1-D24-FN1M
Type B :
- Type B+ :
- Type C :
D-Sub25pin (plug)
RS-232C/422
D-Sub9pin (plug)
RS-232C/422/485
Serial I/F (COM2)
-
D-Sub9pin (socket)
RS-422/485
Ethernet I/F
-
NEW!
10BASE-T/100BASE-TX
FLEX NETWORK I/F
✔
DIO I/F (COM1)
Type B :
- Type B+ :
DIO 32 points
Input : Sink/Source 16 points
Output : Sink 16 points Type C :
-
-
CF Card I/F
-
NEW!
✔ *1
USB Host I/F
-
NEW!
✔(Type A) *1
Printer I/F
-
NEW!
USB *1
Alarm Output
✔
- *1
*1 There are some restrictions regarding replacement with recommended substitutes.
*2 When LT Type B+ is replaced with GP-3300T/L, the I/O units that were connected to LT Type B+ via the DIO interface before replacement are connected via a FLEX NETWORK interface. A FLEX NETWORK unit is required.
When the display unit type is changed to AGP-3300T/L-FN1M, the I/O setting at the time of using LT Type B/B+/C is all cleared. Check the setting of the LT Type B/B+/C project file (*.prw) and allocate I/O to the GP-3300T/L project file again.
◆ FLEX NETWORK Interface Specifications
LT Type B/B+/C
GP-3300T/L
Communication Configuration
1:N
Connection Method
Multi-Drop Connection
Max. Distance
200m/channel at 6Mbps
100m/channel at 12Mbps
Communication Method
During cyclic period, distributed transmission, Half-duplex
Communication Speed
6Mbps/12Mbps (selectable)
Communication I/F
Differential Method, pulse transfer resistance
Error Check
Format, bit, or CRC-12 verification
Max. Number of Nodes
63 (max)
1008 I/O points
(depending on type of units used)
Bit variable input : 512 points *1
Bit variable output : 512 points *1
Integer variable input : 128 points *2
Integer variable output : 128 points *2
(depending on type of units used)
*1 When using GP-Pro EX under Ver.2.50, Bit variable enables to input/output 256 points.
*2 When using GP-Pro EX under Ver.2.50, Integer variable enables to input/output 64 points.